If your heating system in Santa Fe, NM is not working it is likely your boiler needs repair or a good servicing. At times the fix is simple, at times not. Our heating service technicians have years of experience working on hot water or steam boiler systems like yours in Santa Fe, NM. Reliable Tech Heating Cooling and Plumbing service vehicles are on call 24 hours per day are fully equipped with the tools and parts necessary to get your furnace back up and operating.
Our boiler repair, service or replacement pricing is competitive. Our estimates are always firm with no hidden surprises. You can rely on Reliable Tech Heating Cooling and Plumbing to advise you properly and to do excellent work promptly.


Tech performed boiler inspection and drained and flushed water heater.

La Avendia San Marc, Santa Fe, NM SANTA FE, NM
2017-11-14


Tech performed boiler check and flushed water heater. Boiler and water heater are working properly at this time. Also tightened compression fittings on sink drain

Buster Ridge SANTA FE, NM
2017-11-07


Technician performed diagnostic check on Lochinvar Boiler. Recommend fernox treatment of system. Also inspected water heater and replaced batteries on thermostats.

Pajartio Peak SANTA FE, NM
2017-11-07


Tech performed diagnostic check on boiler and water heater. water pressure for domestic water is excessive at 90 psi.

Betatakin Circle SANTA FE, NM
2017-11-06


Tech completed inspected on lochinvar boiler system. Pressures were good, wiring was checked, expansion tank is good all zones were tested and fired up. Tech recommended repair on the leak at super vent office, will schedule the repair time.

Canyon Rd Unit E SANTA FE, NM
2017-11-06


Leak on boiler, in expansion tank. Needs to be replaced. Also pump is unopenable. System at 10 psi needs replacement, gas leak @ gas valve on pilot tube connection. Needs to be repaired before unit can be turned back on.

Lujan St. SANTA FE, NM
2017-11-03


Boiler No heat. Tech replaced thermal couple on Weil Mclain boiler system, unit was tested and is working. Tech recommended fernox.

Via Bosque SANTA FE, NM
2017-11-03


Boiler No heat. Tech replaced thermal couple on Weil Mclain boiler system, unit was tested and is working. Tech recommended fernox.

Via Bosque SANTA FE, NM
2017-11-03


Boiler inspection all pumps are operating properly. Tstats are operating properly. Air vent needed and T&P boiler.

Cumbre Vista, Santa Fe, NM SANTA FE, NM
2017-11-02


Tech found rust build up on 2004 Lochnivar due to corrosion.

Brimhall wash SANTA FE, NM
2017-11-02


Checked previous plumbers piping work. Service contract

Gregory Lane, Santa Fe, NM SANTA FE, NM
2017-10-27


Tech completed boiler inspection. Pressures are correct and burners are clean. Each zone was tested and turned on wires are good. No cracks or knocks. Customer needs info on fernox boiler treatment.

Calle De Montanas SANTA FE, NM
2017-10-27


Boiler no heat.

Coyote Springs Rd SANTA FE, NM
2017-10-19


2-4ppm of CO was read in cabinet. Boiler was red tagged (238) until repairs are made.

A county road 84, Santa Fe, NM SANTA FE, NM
2017-10-18


Weil Mclain CGa gold - everything is in great working condition on boiler system.

Avenida Colima, Santa Fe, NM SANTA FE, NM
2017-10-18


Install new venting in the mechanical room, up to the ceiling and install a 1 1/4

Calle De Montanas SANTA FE, NM
2017-10-13


Trane 5 ton package unit. Leak not in duct work, no signs of water marks or soaked insulation in duct.

Camino Rojo, Santa Fe, NM SANTA FE, NM
2017-10-11


Tech completed maintenance on Weil McLain cga gold boiler system, system is running correctly.

Old Galisteo Rd, Santa Fe, Nm SANTA FE, NM
2017-10-09


Tech did CO test and made sure functions of boiler were good.

Avendia De Las Americas, Santa Fe, NM SANTA FE, NM
2017-10-05


Relight boiler pilot light

Rio Guicu, Santa Fe, NM SANTA FE, NM
2017-10-03